{"product_id":"autool-lm150-digital-3-way-full-kit-auto-a-c-pressure-gauges-refrigerant-manifold-gauge-manometer","title":"AUTOOL LM150 Digital 3 Way Full Kit Auto A\/C Pressure Gauges Refrigerant Manifold Gauge Manometer","description":"\u003ch2\u003e\u003cspan data-mce-fragment=\"1\"\u003eLM150 Digital Manifold Pressure Tester\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp\u003e\u003cspan data-mce-fragment=\"1\"\u003eAUTOOL LM150 is a new generation of multi-functional intelligent auto digital refrigerant manifold gauge introduced to the market. This product can be used as an auxiliary measuring instrument for the installation, testing and maintenance of auto air conditioner and other refrigeration equipment. It is characterized by dual pressure test, dual temperature test (test clips required), leak detection, digital display, multi-unit conversion, multi-mode function and refrigerant parameter database. Adopting the new ball valve structure, it has the advantages of sturdiness, rapid opening and closing, easy operation, safety and reliability, accurate and stable control, etc. It is committed to solving the diagnostic and maintenance problems of air-conditioning and other refrigeration systems for users.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch4\u003e\u003cstrong\u003eEvaporating Pressure and Temperature Measurement\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003eMeasure the maximum pressure when the refrigerant changes from liquid to gas, and the minimum temperature when the liquid changes to gas (the lower the evaporating pressure, the lower the evaporating temperature, the higher the refrigeration cycle efficiency, and the greater the refrigeration capacity).\u003c\/p\u003e\n\u003ch4\u003e\u003cstrong\u003eCondensing Pressure and Temperature Measurement\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003eMeasure the minimum pressure when the refrigerant changes from gas to liquid, and the maximum temperature when the gas changes to liquid (the lower the condensing pressure, the lower the condensing temperature, the higher the refrigeration cycle efficiency, and the greater the refrigeration capacity).\u003c\/p\u003e\n\u003ch4\u003e\u003cstrong\u003eHigh Pressure, Low Pressure and Temperature Measurement\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003eMeasure the pressure and temperature of refrigerants in high and low pressure pipes in air conditioner systems (requires connection of test clamps)\u003c\/p\u003e\n\u003ch4\u003e\u003cstrong\u003ePressure Maintaining and Leakage Test\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003eThe pressure difference between the initial test pressure and the secondary test pressure is calculated to determine whether the refrigerant is leaking.\u003c\/p\u003e\n\u003ch4\u003e\u003cstrong\u003eMultiple Test Modes\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003eAUTOOL LM150 Refrigerant Manifold Gauge can measure dual pressure (high and low pressure), and dual temperature measurement (high and low pressure pipeline temperature, need to connect test clamps), measure the percentage of vacuum degree; it has the functions of pressure leakage measurement, leakage time and speed recording, pressure multi- unit conversion, temperature Celsius \/ Fahrenheit Conversion, etc., to meet the different needs of users.\u003c\/p\u003e\n\u003ch4\u003e\u003cstrong\u003eRefrigerant Type Setting and Visual Window\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003eAUTOOL LM150 Refrigerant Manifold Gauge can be set according to the type of refrigerant that needs to be filled in the auto, and the filling state of refrigerant can be observed through the visual window. \u003c\/p\u003e\n\u003ch4\u003e\u003cstrong\u003eMulti-unit Conversion\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003eEquipped with pressure multi-unit automatic conversion, temperature Celsius \/ Fahrenheit automatic conversion.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch4\u003e\u003cstrong\u003eHigh Pressure, Low Pressure and Temperature Measurement\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003eMeasure the pressure and temperature of refrigerants in high and low pressure pipes in air conditioner systems (requires connection of test clamps)\u003c\/p\u003e\n\u003ch4\u003e\u003cstrong\u003ePressure Maintaining and Leakage Test\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003eThe pressure difference between the initial test pressure and the secondary test pressure is calculated to determine whether the refrigerant is leaking.\u003c\/p\u003e\n\u003cdiv\u003e\u003cimg alt=\"\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0599\/3303\/2643\/files\/Screenshot2024-02-20at1.53.47PM.jpg?v=1713927429\"\u003e\u003c\/div\u003e\n\u003cdiv\u003e\u003cimg alt=\"\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0599\/3303\/2643\/files\/Screenshot2024-02-20at1.51.37PM.jpg?v=1713927461\"\u003e\u003c\/div\u003e\n\u003cdiv\u003e\u003cimg alt=\"\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0599\/3303\/2643\/files\/Screenshot2024-02-20at1.51.52PM.jpg?v=1713927486\"\u003e\u003c\/div\u003e\n\u003cdiv\u003e\u003cimg alt=\"\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0599\/3303\/2643\/files\/Screenshot2024-02-20at1.52.39PM.jpg?v=1713927507\"\u003e\u003c\/div\u003e","brand":"Autool","offers":[{"title":"Default Title","offer_id":42807005413571,"sku":"autlm150","price":240.0,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0599\/3303\/2643\/files\/C-Pressure-Gauges-Refrigerant-Manifold-Gauge-Manometer-Autool-72484791.jpg?v=1705481630","url":"https:\/\/fairtools.nz\/products\/autool-lm150-digital-3-way-full-kit-auto-a-c-pressure-gauges-refrigerant-manifold-gauge-manometer","provider":"FairTools","version":"1.0","type":"link"}